101804 85mm 7 101805 95 8 101806 105 9 101807 115 10 Femoral Arches, Stainless Steel Arch Size 201002 90° Small 201004 120° Small 201006 90° Large 201008 120° Large Oblique Support Connection, Stainless Steel Cat No 201300 Long Connection Plates, Composite Length Holes 100420 155mm 8 100421 235 12 Length Holes Long Connection Plates
options – 85mm and 140mm Each kit includes: - End effector coupling kit - 10-meter communication cable - RS485 to RS232 converter - RS485 to USB converter - Screw kit - Quick start guide 85 kit: AGC-OMRON-KIT-85 140 kit: AGC-OMRON-KIT-140 Robotiq Hand-E gripper for OMRON TM robot A 2-finger parallel gripper with an IP67 rating 50mm stroke
developed the Multi-Pin Clamp technique Over the next 60 years, external fixators continued to become more rigid In most cases, they were used as a primary means of fracture management Since the 1980s, however, the use of external fixation has evolved to become a temporary way to support soft tissues
TM 4 75 Deformity System—Surgical Technique Guide 17 STRAIGHT CONNECTORS LESS-CURVED CONNECTORS (LIGHT GREEN) MORE-CURVED CONNECTORS (LIGHT BLUE) LENGTHS 60mm 80mm 80mm 85mm 100mm 100mm 115mm 120mm 120mm RADIUS N/A 500mm 250mm The Polaris 4 75 System provides the ability to perform in situ distraction of the spine via unique axial connectors
compensation in an advanced 4mm x 5mm x 1 85mm 30-pin QFN package The EN6310QI is specifically designed to meet the precise voltage and fast transient requirements of present and future high-performance, low-power processor, DSP, FPGA, memory boards and system level applications in distributed power architectures
FT930Q-X 68 Pin QFN, pitch 0 4mm, body 8mm x 8mm x 0 85mm, supports ADC/DAC, SD-Card, and RTC features FT931Q-X 56 Pin QFN, pitch 0 5mm, body 8mm x 8mm x 0 85mm, supports ADC/DAC, SD-Card, and RTC features FT932Q-X 48 Pin QFN, pitch 0 5mm, body 7mm x 7mm x 0 85mm, supports ADC/DAC and SD-Card features, no RTC feature
Nail System permit a more percutaneous technique and less tissue stripping than current treatment methods An in-tramedullary approach shows decreased blood loss versus plate fixation of subtrochanteric fractures 10,11 Use of the 11 0 mm helical blade results in reduced bone removal com-pared to a hip screw Early, active mobilization
3 5 mm VA-LCP Proximal Tibia Plate System Surgical Technique DePuy Synthes Trauma 11 Plate Insertion and Fixation Choose the adequate plate length, side and type (small/ large bend) and place it on a flat surface to allow the correct assembly of the insertion handle to the plate Note: The VA-LCP Proximal Tibial Plates are
2 rEQUirEmEnt sPECifiCation notEs Portable Yes Provided with a carry bag Strap can be used to attach to IV pole or foot of bed Pressure Range -40 to -200mmHg 40, 50, 60, 70, 80, 90, 100, 120, 130, 140, 150,
fixation à la structure qui doivent être choisis selon le type de support et la charge estimée *** Assemblage par boulons ø 6 mm non fournis SYSTÈME PROFILS LONGUE PORTÉE (PLP)
Epaisseur minimum du support (h min) en mm 120mm 130mm 150mm 165mm 210mm Vu la diversité des matériaux pouvant servir de support d'ancrage aux différents types de fixation, les données techniques ne doivent servi qu'à titre indicatif Dans de nombreux cas, le recours à une série de tests de validation du type et de la dimension recommandée est nécessaire
Consulter le support technique et/ou notre base de données techniques disponible sur notre site internet et mise à jour régulièrement Les photos et les dessins ne sont donnés qu’à titre indicatif et ne constituent nullement des documents contractuels
support : bois, béton ou acier Exemples : grâce à la technique dite de “la boîte dans la boîte” On réalise alors des portiques indépendants de la structure d’accueil, avec les profilés et accessoires Stil Prim® et Multiprim® • Performances feu : - Le système Placostil® Prim associé aux fourrures et entretoises PRF Stil® F 530et aux plaques Placoflam® ou Glasroc F
Cette technique procure une excel lente continuité de l’isolation du sol au plafond ainsi qu’un calfeutrement parfait autour des huisseries Il n’y a pas de lame d’air parasite entre le mur support et l’isolant ainsi qu’à la jonction entre panneaux
Dossier Technique sur des bâtiments de catégorie d’importance I, II, III et IV, situés en zone de sismicité 1 (très faible), 2 (faible), 3 (mo-dérée) et 4 (moyenne), sur des sols de classe A, B, C, D et E Prévention des accidents et maîtrise des risques lors de la mise en œuvre et de l’entretien
Surgical Technique Confirmation of Screw and Drill Bit Length 12 Maxillary/LeFort I Plate Fixation 13 Sagittal Split Fixation 16 • BSSO Plate 16 • SplitFix Plate 20 Genioplasty Fixation 25 Vertical Ramus Osteotomy Fixation 28 Product Information Implants 34 Instruments 39 Modules 44 Additionally Available 45 References 48 2 DePuy Synthes MatrixORTHOGNATHIC Surgical Technique